24 Vac Dual Intermittent Pilot Gas Valve with 1/2 in. x 3/4 in. inlet/outlet, standard opening and 3.5 in. wc pressure regulator setting
Overview
Combination gas control for use in 24 Vac, gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh.
Features
• Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
• Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control Modules.
• Compact size.
• Provide two automatic valves. Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
• Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
• Meet codes requiring dual safety shutoff.
• Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available.
• All adjustments, wiring connections and pilot outlet are accessible from top of control.
• Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.
• Compatible with ECO connector.
• ON-OFF lighting sequence.
Product Specifications
Description 24 Vac Dual Intermittent Pilot Gas Valve with 1/2 in. x 3/4 in. inlet/outlet, standard opening and 3.5 in. wc pressure regulator setting
Type Single Stage
Ignition Type Intermittent Pilot
Type of Gas Natural
Inlet/Outlet Size (in.) 1/2 in. x 3/4 in.
Body Pattern Straight-through
Opening Characteristics (standard, step) Standard
Capacity @ 1 in. p.d. 270,000 BTU/hr; 30,000 BTU/hr minimum
Pressure Ratings (psi) 1/2 psi
Pressure Ratings (kPa) 3.5 kPa
Pressure Regulator Setting (psi) 3.5 in. wc
Pressure Regulator Setting (kPa) 0.87 kPa
Pilot Gas Outlet Compression fitting for 1/4 in. OD tubing
Pressure Tapping 1/8 in. NPT with plug
Electrical Connections 1/4 in. male quick-connects
Electrical Ratings 24 Vac
Frequency 60 Hz
Anticipator Setting 0.7 A
Temperature Range (F) -40 F to +175 F
Temperature Range (C) -40 C to +79 C
Mounting 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Dimensions (in.) 5 3/8 in. high x 4 1/16 in. wide x 2 11/16 in. deep
Dimensions (mm) 135 mm high x 104 mm wide x 69 mm deep
Includes One 3/4 in. x 1/2 in. reducer bushing; 393691 Natural to LP gas conversion kit.
Approvals, American Gas Association IAS AGA Design Certified: File No. L2025007.
Approvals, Canadian Gas Association CGA Design Certified: File No. L2025007.
Approvals, Underwriters Laboratories Inc UL Component Recognized: File No. MH5323.
Replaces Gas Valve Part Numbers:
VR8440M2008
VLV42A-602
VR8440A2076
VR8440M3648
UR8440A2076
VR8304M 3509
VR8304M3509
VR8440A 2068
VR8440A2068
VR8440M 1018
VR8440M1018
VR8440M 1034
VR8440M1034
VR8440M 3006
VR8440M3006
VR8440M 3022
VR8440M3022
VR8440M 3030
VR8440M3030
VR8440M 3048
VR8440M3048
VR8440M 3055
VR8440M3055
VR844A 1036
VR844A1036
VR844M 1022
VR844M1022
VR844M 1048
VR844M1048
VR844M 1071
VR844M1071
VR844M 1097
VR844M1097
VR844M 1105
VR844M1105
VR844M 1113
VR844M1113
VR844M 1121
VR844M1121
VR844M 1147
VR844M1147
VR844M 1154
VR844M1154
VR8304M 3103
VR8304M3103
VR8304M 3111
VR8304M3111
VR8304M 3129
VR8304M3129
VR8304M 3152
VR8304M3152
VR8304M 3160
VR8304M3160
VR8304M 3178
VR8304M3178
VR8304M 3186
VR8304M3186
VR8304M 3517
VR8304M3517
VR8304H4503
VR8304M4507
A15691-600R
VLV49A-600R
VR8345M4302
VR830MH3505
VR8440A3025
VR8440A6028
VR8440A6036
VR8304M3509
SP10963B
CARVR8304M3509
Used in Rheem Ruud Equipment Models:
G50-98
RFD67
RFD67-120-1