VERY IMPORTANT NOTE!!! NOT FOR USE WITH DIRECT VENT OR MOBILE HOME SYSTEMS!!!
Modernization Upgraded Kit used to replace obsolete Gas Controls.
•236B8E
•>
Used to Upgrade Furnaces and Boilers
We offer FREE Tech Support when you purchase any part from us.
If you need Installation help no problem please call us
Honeywell Relight Ignition Upgraded Replacement KIT:
Y8610U Universal Retrofit Intermittent Pilot Gas Burner Ignition System Complete kits converting conventional standing pilot system to intermittent pilot system. For use with 24 Vac gas-fired atmospheric furnaces, boiler and heating appliances.
INLET GAS LINE SIZE: 3/4" or 1/2"
OUTLET GAS LINE SIZE:3/4" or 1/2"
Used Existing Pilot Light
Gas Pipe Reducing Bushings Included.
Honeywell Y8610U kits are for use with Natural or LP Gas: provides 100 percent pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated.
Ignition trail/delay sequence is repeated until the appliance lights or call for heat is removed.
Replaces these Obsolete Furnaces Models with outdated parts no longer available from the original manufacture:Rheem RGEC-04NACR.
Product Specifications:
Ignition System Type Intermittent Pilot.
Ignition Sequence Continuous retry [after trial for ignition, pilot gas shuts off for 5 minutes, then another trial for pilot.
ignition takes place] Flame Sense Single Rod Ignition Source Internal high voltage spark generator Prepurge (sec) none.
Flame Failure Response Time (sec) 0.8 sec @ 1.0 microamp.
Typical Ignition Hardware Q345, Q3451.
Typical Gas Control VR8304M Dual Valve Combination Gas Control.
Gas Type L.P./ Natural
Description Provide electronic control of intermittent pilot ignition systems used on gas fired furnaces, boilers, and other heating appliances.
Dimensions (in.) 3 15/16 in. high, 5 7/16 in. wide, 2 5/8 in. deep.
Dimensions (mm) 100 mm high, 138 mm wide, 67 mm deep.
Control Voltage (Thermostat or other call for heat) 24 VAC / 60 Hz.
Electrical Ratings (Vac) 24 Vac.
Frequency (Hz) 60 Hz
Temperature Ratings (max. ambient)(C) -40 C to +74 C.
24 volt spark ignition gas valve kit
Temperature Ratings (max. ambient)(F) -40 F to +165 F.
Replaces Gas Valves in Lennox Furnace Models:
G11-110
G12D-110-4
G12D1104
G50RBG-3
EF33C2189
G11Q3E-137V-6
G11Q3E-137-V-6
G12Q4E-110-4
G12Q4E-SERIES
G12Q5E-1659
G12Q4E-137-14
G12Q4E-Series
G12Q3E-110-6.
**NOTE** THIS MODERNIZATION KIT DOES NOT COME WITH THE PILOT ASSEMBLY! IN MOST CASES YOU WILL USE YOUR OWN PILOT. IF YOU NEED A PILOT ORDER A UNIVERSAL PILOT FOR MOST MODELS PART NUMBER PIL9962H LOCATED AT THE BOTTOM OF THIS PAGE! **
24V Mercury Element with Pilot Gas Relay Operator Bimetal 2nd Stage Regulator Non-Adjustable
1585938
1585967
1585-967
1585967
1585968
36C93-301
36C93301
Suggested Replacement: None Upgrade to a Modernization Electronic Ignition Kit
5059-122
36C76-224
36C76224
30A48-1
36CBA-201
36C84-202
30A48-5.
Replaces Obsolete Robertshaw Gas Valves:
7000BKER-S7B
7100DER-S7A.
Replaces Obsolete Gas Controls in Dayton, Rheem, Ruud Furnaces:
3E377
HC802421C
RGAA-05KCD
UGAA-05KCD
WGAA-05KCD
RGAA05KCD
UGAA05KCD
WGAA05KCD
RGAA-050AA
UGAA-050AA
WGAA-050AA
RGAA050AA
UGAA050AA
WGAA050AA
48DC004
RGDA-06KC-ER
UGDA-06KC-ER
WGDA-06KC-ER
RCAC12KA
RGAA-14KA
UGAA-14KA
WGAA-14KA
WGDC-12EC-JS
UGDC-12EC-JS
RGDC-12EC-JS
RRGG-05E30JKR
WRGG-05E30JKR
URGG-05E30JKR
RRGG05E30JKR
WRGG05E30JKR
URGG05E30JKR
Z10-URG-05E30JKR-01R.
Replaces Coleman, York Obsolete Ignition Modules in Furnace Moddels:
D8SA060N16025A
D8SA60N16020A
CGH050
CGH0100
CGH125
CGH07512D.
Upgrade Furnace Brands: Gaffers & Sattler:
ACD-U 80-1
ACD 13-UBO-4.
Used to up graded Older Model Furnaces:
BLU080E942B1
BKU080E942B1
36/80YAC108TC
DMS4-275-350
L5A112C16-1
HEHB120
867.763334
GWF100A012AIN
R100D0N201
HSC400-6-S-2
Replaces Gas Valve and Ignition Module Part Numbers:
Used to Relace Obsolete Furnace Models:
400DVI
UBS65-94
UCF175-55
GPH-80
G12Q3-82-4
100HCDAC
TDN090A
GSE50DN-3
BGLD100CB01.
Used to Upgraded Boilers: 36C98 Type
Replaces Obsolete Gas Valve Part Numbers:
P233500
P216600
8-2955D
V400M1357
73A5601
13H4501
39C84-235
36D24-401
Q362A1011
Q361A1013
Q361A1005
507356
36C93-301
3046-25
36D13-405
3093-111
3093111
S9301A1001
G60PAG-1
525-32571-000
VR852M1005
Y8610U3003
25G53
25G53A404
25G53A-404
25G53-404
LO-15
3056-2
L0-15
RO198384
25C46-204
3098-151
R0198384
R0198575
R0198575
Y8610
V8800A1071
Y8610U
SX613-300
P9661209F
300844
3049-537
36C84-220
FS-1
8D48A-702
77402
CAR5E757
CARY8610U3003.
S8610U Intermittent Pilot Module.
• VR8204 Intermittent Pilot Dual Valve Combination Gas Control with an
ON-OFF manual valve, pressure regulator and two automatic main gas
valve operators. Includes reducer bushings.
• 393691 LP Gas Conversion Kit.
• 392431 Igniter-Sensor Assembly. Includes ceramic-insulated Kanthal rod
that attaches to the existing pilot burner in place of the thermocouple.
• 394800-30 Ignition Cable. 30 in. [762 mm] cable with connectors.
• 393690-14 Flange Assembly. Includes 3/4 in. straight flange with O-ring,
9/64 hex screws and wrench.
• Wiring Harness. 30 in. [762 mm] wiring harness with 1/4 in. quick-connect
terminals.
• Reducer bushings for gas control.
• Adhesive mounting tape for S8610U module.
•Miscellaneous installation hardware
• screws, solderless connectors,
ground rod and adapter.
ELECTRICAL RATINGS:Voltage and Frequency
• 24 VAC (nominal), 60 Hz.
Current Rating
• 0.7A (includes both module and gas control).
THERMOSTAT HEAT ANTICIPATOR SETTING
• 0.7A plus current ratings of
other devices in thermostat control circuit.
Compatible with all open-close switch type 24 VAC thermostats capable of
supplying rated voltage and current to the module.
Also compatible with Honeywell electronic thermostats that directly switch the ignition module.
NEW PILOT OPTIONAL:
OPTIONAL PARTS LISTED BELOW