Overview:
This controller provides precision control for mixed air dampers,heating and cooling valves,air units,chillers,laboratories,computer rooms,test chambers,and other applications.

Features:

• System 8000 two input controller

• Automatic Reset Action

• Control signal inversion capability

• High signal selection

• Ramp up and ramp down operation

• Anti wind-up capability

Specifications:
Sensors:
Temperature: TS-8000 series one or two;three sensors through a CN-8101 multi-purpose bridge.
Humidity: HS-8x01,VER-HDxx-MSx,VER-HOxx-MSx,VER-HxWx-MA.
Setpoint adjusters: SPA and SPB,41 to 95 qF (5 to 35 qC).
Remote setpoints: Order separately AT-8122,AT-8155,or AT-8158.
Throttling range: 10
•F degrees (5
•C degrees)factory set,20 and 30
•F degrees (11 and 17
•C degrees)pin selectable.
Authority ratio adjustment: Factory set 1:1,pin selectable 0.5,0.75,15:1,others available.
Bridge action: Factory set,
•A
• ,D.A.(direct acting),
•B
• R..A.(reverse acting),can be made reverse acting.
Auxiliary bridge input: For remote setpoint adjusters,night setback,etc.
Control amplifier output voltage (OP1): 2 to 15 Vdc.Unit factory calibrated for 7.5 Vdc output with sensor at setpoint temperature.
Integral action time: Dial adjustable 0.3 to 3 repeats per minute.
Integral action limiter: Limits output signal from integral action section to 2 Vdc above input signal in ramp up mode or 2 Vdc below input signal in ramp down mode.
Anti-wind-up or down: On system startup,normal proportional control signal from OP2 until the input voltage to IV1 is less than 7.5 Vdc (anti-wind-up)or greater than 7.5 Vdc (anti-wind-down),at which point integral action is initiated.
Signal inversion: Adjustable at SPC from 5.5 Vdc above or below the input signal at IV2.
Softstart: On system startup.
Time: Adjustable 3 to 60 minutes for 3 Vdc output change.
Start: point Adjustable 0 to 15 Vdc.
Restart: Momentary contact closure between RST and COM restarts ramp function.
Power requirements: 20 Vdc,40 mA +2 mA per System 8000 controlled device.
Power supply available: 6.2 Vdc 4 mA maximum.This regulated and filtered power supply must not be connected to +6.2 or red lead of other supplies.
Calibration potentiometers: Internal.
Number of controlled devices: Maximum of six System 8000.
Environment:
Ambient temperature limits: Shipping and storage:-40 to 160 qF (-40 to 71 qC). Operating:40 to 140 qF (4 to 60 qC).
Humidity: 5 to 95%RH,non-condensing.
Locations: NEMA Type 1 indoor only.
Connections: Coded screw terminals.
Cover: Aluminum.
Mounting: Unit provided with plastic track for panel mounting.AD-8912 enclosure can be ordered separately for remote installations.
Dimensions: 4 H x 7-1/2 W x 2-1/2 D in.(102 x 191 x 64 mm).

Replaces Part Numbers:
CP-8122 CARCP8122


I called trying to find out what happened to the rest of my order and was surprised to hear a warm and kind voice willing to do whatever it takes to find answers and follow through with her promise. Amanda is an asset worth holding on to and a credit to your company. She was very professional, helpful and courteous while assisting me with my order. I would most definitely assign her an A+ in customer service."
Donald "Brad" Thomas

I would like to thank you for your hard work in getting us our part in a timely fashion. You were very helpful and you understood the severity of the situation and did a wonderful job in getting the part to us. Thanks again and please share this with your boss! You were outstanding!"
Todd Mills

Share This:
Quantity:
In-Stock
Have Questions? Prefer to order by phone?
Our parts Experts are happy to help!

Call Monday to Friday 10am - 6:30pm EST
1-866-432-8551 or Email our Parts Experts
Accredited BusinessGo DaddyAuthorize.net
Amanda I want to thank you, the blower fan work perfectly. Thank you so very much."
Bill K Roberts
Amanda, Thank you very much again, I have been looking for this part for about two weeks and getting very frustrated in the process of the search, you were very helpful!!"
Ken Holm
Why Buy From Us?
110% Lowest Price Guarantee
Over 500,000 Parts in Stock
Same Day Shipping on Orders Received Before 3pm EST (Mon-Fri)
Nationwide Distribution Centers for Fast Delivery
Choose from UPS Next-Day, 2-Day, 3-Day and Ground Service
We Supply Retail and Wholesale
Order from us.
Risk Free, with
Our Triple Guarantee
Guarantee 1
No hassle, 30-day returns policy
Guarantee 2
110% Lowest price guarantee
Guarantee 3
90-day warranty
Sign up for Special Offers Directly from AmericanHVACParts.com
AmericanHVACParts.com | 548 N. 13th Ave., Suite 302 | Upland, CA 91786
© 2005-2014 AmericanHVACParts.com. All Rights Reserved.