208/230 Volt 1-Phase Tecumseh Carrier Air Conditioning Compressor:
Replaces Compressor Part Numbers:
AH31S13V
AH31S13U
AHG256
P-8-7468
P-8-7774
P-8-3558
41K4301
AH152HT-097
AH152HT097
015-01835-000
01501835000
015-02665-701
01502665701
015-02309-002
01502309002
015-02371-002
01502371002
015-01524-000
01501524000
AH5531E
H7265E
20410
H21A313ABCA
AH5531E
24250001
1220236
AWG5530EXN
AW5530E
AH152GT-090
AH152GT090
AH152HT-015
AH152HT015
AH152HT-031
AH152HT031
AH152HT-028
AH152HT028
WW77X906
P-8-8037
P88037
P031-3122
GB15QF001
P031-3121
P031-3124
P031-3025
AW708ET-093
AW707ET-093-J7
AWG5530EXN
AWG5532EXN
63K71
63K7101
P031-2823
P031-2821
P031-3022
50SR661341
50YH660300
51FE660300
AW108FT-014
AW5532E
AWA5532EXD
AW707ET-093
P031-3122
63371001
1162520
1053387
1220079
1162869
1162520
913881
AWG5530EXN
AW707ET-103
AW5530E
P031-3025
AW707ET-093-J7
CARB94890
CARB81803
CARAWG5530EXN.
H.P. Rating:2-1/2
Type: Reciprocating
Refrigerant: R-22
Frequency: 60
Volts: 208/230
Phase: 1
Used in Signature Air Conditioning Models:
SRM 51209B
SRM51209B
Used in Carrier Air Conditioning Models:
692ANX030000ABAA
565AJX030000AAAA
585EJW030075 B
585GJW030040 B
50YH030300
596ANX036000AAAA
50YM030301
38TKB030300
38GP030300
38ES030300
38ES030320DL
48DL003380
48DL003390
541AJX030000 B
48DL029300AB
48DL029300BB
48DL029300CB
38QHX030300
585EJW030050CA
585EJW030050CB
38GS003200
38GS003300
38GS030200
38GS030300
38GC003320
30/80YAC106
30/80YAC106T
30/80YAC506T
38GC103200
38GC103210
38GF003340
38GF003350
38TG030300
51FL222300
51FL224320
51FLA224320
51FY324310
38GF103200
38GF103210
38GF103310
38GF103320
38GF103340
38GF103350
590ANX030000AAAA
38GC003350
38GC103310
38GC103320
38GC103340
38GC103350
585EJW030075CA
585EJW030075CB
585F1030075
691ANX030000ABAA
Used in Lennox Air Conditioning Models:
HP8-311-1FFP
HP8311 1FFP
HP83111FFP
HP19311-3P
Used In ICP Equipment Model Numbers:
CU30CQC1
Below are some common questions about our compressors. If you have a question that is not addressed below, please send us an e-mail attention *parts departmaent*. What oil is used in an R-12 compressor manufactured today
• Synthetic alkylate. What is synthetic alkylate oil
• Synthetic alkylate is another name for alkylbenzene, which is used in many of our hermetic compressors. Is 3GS mineral oil compatible with "white oil" and alkylbenzene oil
• Yes. They have different properties, but are chemically compatible. How long may I leave a compressor charged with POE oil open to the atmosphere
• No more than 15 minutes maximum. Can blends be charged as vapor
• No. Blends must be charged in liquid phase. Can R-410A be used in a compressor designed for R-22
• No. Tecumseh is currently developing a line of R-410A compressors. What is the highest acceptable motor winding temperature for your hermetic motors
• 265 degrees Fahrenheit, measured by the resistance method, is the highest acceptable temperature for our hermetic motors. At what speed do your hermetic compressors run
• Our 60 Hz. compressors run at a nominal 3450 rpms at rated voltage, and our 50 Hz. compressors run at 2,875 rpms. Can I use a "one size fits all" type of start relay on all of your hermetic air conditioning compressors
• No. Tecumseh Engineering department has selected specific relays for each compressor to meet there starting specifications. I don't have the correct voltage rating on a run capacitor, as specified in your literature; can I use a different voltage rating
• Yes. The voltage rating of all capacitors must be the same as, or greater than, the specified voltage. If I am replacing a failed compressor with a like new compressor can I use the electrical components from the old compressor on the new compressor
• You should use only new electrical components (e.g. relay, start capacitor, run capacitor) designed for use with the new compressor. Is it safe to use leak detection dyes in air conditioning and refrigeration systems
• Tecumseh Products Company does not endorse the use of any substance in the system except the oil and refrigerant designed for use in the specific compressor. Do your capacitors contain PCB oil
• Since January 1979, capacitors provided by Tecumseh have contained non-PCB oils. Do your compressors contain PCB's
• No. Do you have a mathematical equation and coefficients for your compressors' performance data
• Yes. We publish compressor performance information to our OEM's in the ARI Standard 540 format. In air conditioning applications, how does horsepower compare to Bth/hr.
• At air conditioning rating conditions one horsepower equals 12,000 Btu/hr. Can I use my own grommets on your compressors
• Yes, if they pass your system shipping/transportation and sound/vibration tests. What is "D21"
• Discharge temperature measured with an insulated T/C two inches from the compressor tube to line joint. Why can't I move the electrical warning label or bar code labels
• Readers or scanners in production are fixed and changing would have to be agreed upon by all customers. Safety reasons govern changing electrical label.