Hot Surface Ignition Universal Interated Furnace Control (Honeywell/Robertshaw)
With robust diagnostics and universal application, the Honeywell Hot
Surface Ignition (HSI) Universal Integrated Furnace Control (UIFC)
is the only model you need. Honeywell offers universal compatibility
by way of a complete set of wiring harnesses adapters to simplify
installation. EnviraCOM
•-enabled to work with remote monitoring and
diagnostic systems, the Honeywell UIFC features innovative, robust
diagnostics that make installation and troubleshooting a breeze. Critical
errors are immediately dialed out when connected to a Telephone Access
Module and displayed on the touchscreen of the VisionPRO
• IAQ. Able to replace most furnace
controls and be applied to most heating and cooling single-stage appliances, Honeywell UIFC
•s
are the only brand you need on your truck. Simplify your inventory with the universal choice
•
Honeywell Universal Integrated Furnace Controls.
Save yourself headaches when trying to replace furnace controls with like
for like models
• carry Honeywell Universal Integrated Furnace
Controls (UIFC) on your truck. Featuring universal compatibility and
simplified installation by way of a complete set of wiring harnesses,
having exactly what you need is always a breeze with the UIFC.
One Control Handles It All
Put an end to excessive inventory and searching for the right
model on your truck
• the keyed wire harnesses allows it to
replace nearly all furnace controls and be applied to most
heating and cooling single-stage appliances. Simply put, this
is the only control you need for residential natural or liquid
propane fueled furnaces.
Built-In EnviraCOM
• Communications
Honeywell Universal Integrated Furnace Controls are EnviraCOM
•-
enabled, so you can set up local or remote monitoring and
diagnostic systems
• perfect for selling service contracts.
Because all Honeywell UIFC
•s feature EnviraCOM communications
capabilities, you
•ll have your customers ready for remote services
whether you
•re replacing old controls or installing new equipment
like the VisionPRO
• IAQ, Telephone Access Module (TAM) or
EnviraZONE
•. If a critical alarm occurs, like a rollout switch alarm,
the TAM will call out immediately to notify you of the problem and
an error message will be displayed on the screen of the VisionPRO
IAQ to notify you of the problem. Stay connected with Honeywell
EnviraCOM communications.
Simplified Installation
While models from other brands have unique wiring terminals
requiring a like for like replacement, Honeywell Universal
Integrated Furnace Controls feature universal wiring harnesses
that give you the flexibility you need while in the field and on
the job. Wiring harnesses are included for simple replacement
and installation, and LED indicators provide system status,
performance and diagnostic information. Honeywell has also
mounted the board into a plastic tray which results in an easier
installation and added protection against dust and flexing of
the board. It all adds up to an easy installation.
Proven Reliability
Because the UIFC is built by Honeywell, you know it
•s
engineered for reliability and long-term performance. Safety
and dependability are built into every Honeywell product.
Product Specifications:
Description Universal single stage heating & cooling
Line Voltage 120Vac (97-132 Vac)
Low Voltage 24V (18-30Vac)
Frequency 60 Hz
Operating Temperature (F) -40 F to +175 F
Operating Temperature (C) -40 C to +79 C
Operating Humidity Range (% RH) 0% to 95% non-condensing
Igniter Current 1.0A resistive @ 95Vac output
Thermostat Anticipator Setting (Stage 1 only) 100mA
PrePurge 30 seconds
HSI Warmup Time 17/27 or 30/30 seconds
Trial For Ignition 4, 6, or 8 seconds
PostPurge 15 seconds
Interpurge 60 secods
Ignition Trials Three, two tries if flame is not sensed
Flame Failure Response Time 2 Seconds max @ 1
•A
Number of LEDs 3
Heat On Fan Delay 30 or 60 seconds
Heat Off Fan Delay 60, 90, 120, or 180 Seconds
Cool Fan On Delay 5 seconds
Cool Fan Off Delay 0 or 60 seconds
Gas Control Used With Any 24Vac redundant, direct ignition gas control rated at 1.5A or less. Honeywell VR8205 recommended.
Cooling Contactor Used With Any 24Vac contactor rated at 1.0A or less
Induced Draft Blower Load 2.2FLA / 25LRA max @120Vac
Ciculator Load 14.5FLA / 25LRA max @120Vac
Type of Fan Used With Standard Induction-Type Circulating Fan
Replaces Rheem, Robertshaw, Nordyne, Carrier, BDP, York, Lennox, Robertshaw, ICM, Goodman, White-Rodgers And Honeywell Part Numbers:
1012-925A
1012-925B
1012-925C
1012-955A
1012955A
1012-83-9651B
1012-930
1012933D
1012-933D
1012-83-9336AHSC1
1012-83-9337A
62-24268-01
62-24268-02
62-24268-03
624557
6245570
624557-0
624564
6245640
624591
624591A
624591-A
624591-B
624591-C
624591-D
624628
624628-0
6246310
624631-0
624631A
624631-A
624631-B
710128A
902378
902696
903106
903106
CAR33101972200
CAR03101973000
CAR50A55843
CARB1809913S
6DT-1
6DT-2
61F3
41F-5
03100662000
031-00662-000
031-00662-700
031-01140-000
031-01140-001
031011140002
031-01140-002
031-01140-701
031-01140-702
031.01234.000
031-01234-700
031-01235-700
031-01250-000
0310126700
031-01267-000
031-01267-001
031-01267-001A
031-01284-000
03101933000
031-01933-000
031-01972-000
031-01973-000
031-02166-000
33101933000
331-01933-000
331-01972-200
43101972100
431-01972-100
P03101267001
P031-01267-001
P031-01267-001
PTH031011400-00
G951ADB1401
G951ADB1401C
G951ADB-1401C
G951ADB1402
G951ADB-1402
G951AEB-1403
50T35-743
50A55-120
50A55-143
50A55-285
50A55-288
50A55-438
50A55-(474-571)
50A55-843
50A50-143
50A50-285
50A50-286
50A50-438
1809913
18099-13S
B180996
B1809906
B18099-6
B18099-06
B1809908
B18099-08
B1809910
B18099-10
B18009910
B180099-10
B1809913
B18099-13
B1809913S
B18099-13S
B18009913
B180099-13
ICM280
CARS9200U1000