Tecumseh Air Conditioning Compressor:
Replaces Carrier, Bryant, Payne, Tecumseh Compressor Part Numbers:AVA5542EXT, GB40LF001,
R50QE680002, GB40LF011, AV5558E, AV191ET-047-J7, P031-5721, AVB5558EXN, CARAVB5558EXN, CARB92747, CARP0315721.
COMPRESSOR TECHNICAL:
Type: Reciprocating
Refrigerant: R-22
Frequency: 60
Volts: 208/230
Phase: 1
Model Part No: AVB5558EXN
BOM No: AV190ET-047-A4Y
Application: AC/HP
RLA: 24.8
LRA: 141
Suction Tube ID: 7/8
Discharge Tube ID: 1/2
Start Capacitor P/N: HC95XX020
Run Cap MFD/Volts: CAP45440
Shell HT: 13.9
Crankcase Htr:
Oil Recharge:Yes
Mounting: CAC0013B
BTUHs: 57,500
Approx BTUHs: 40,001 - 60,000
Compressor Part Number P031-5721 Is Used In 25 Carrier Air Conditioning Models:
PA1RPA060000AAWA
0037
PA1RPA060000AAWB
0037
564ABX060000AAAG
0015
48TJF006300
0037
564ANX060000AAAG
0015
764ABX060000AAAG
0015
PA1ZBA060000AAAA
0015
50ZP060300
0015
558DBX060000AA
0037
558DJX060000AA
0037
580DBV060074AA
0037
580DBV060115AA
0037
580DBV060150AA
0037
580DJV060074AA
0037
580DJV060115AA
0037
580DJV060150AA
0037
48TJD006300
0037
50TJ006300
0037
PY1RJA060074AAWA
0037
PY1RJA060074AAWB
0037
PY1RJA060115AAWA
0037
PY1RJA060115AAWB
0037
PA1RJA060000AAWA
0037
48TJE006300
0037
PA1RJA060000AAWB
Below are some common questions about our compressors:
If you have a question that is not addressed below, please send us an e-mail attention *parts departmaent*. What oil is used in an R-12 compressor manufactured today
• Synthetic alkylate. What is synthetic alkylate oil
• Synthetic alkylate is another name for alkylbenzene, which is used in many of our hermetic compressors. Is 3GS mineral oil compatible with "white oil" and alkylbenzene oil
• Yes. They have different properties, but are chemically compatible. How long may I leave a compressor charged with POE oil open to the atmosphere
• No more than 15 minutes maximum. Can blends be charged as vapor
• No. Blends must be charged in liquid phase. Can R-410A be used in a compressor designed for R-22
• No. Tecumseh is currently developing a line of R-410A compressors. What is the highest acceptable motor winding temperature for your hermetic motors
• 265 degrees Fahrenheit, measured by the resistance method, is the highest acceptable temperature for our hermetic motors. At what speed do your hermetic compressors run
• Our 60 Hz. compressors run at a nominal 3450 rpms at rated voltage, and our 50 Hz. compressors run at 2,875 rpms. Can I use a "one size fits all" type of start relay on all of your hermetic air conditioning compressors
• No. Tecumseh Engineering department has selected specific relays for each compressor to meet there starting specifications. I don't have the correct voltage rating on a run capacitor, as specified in your literature; can I use a different voltage rating
• Yes. The voltage rating of all capacitors must be the same as, or greater than, the specified voltage. If I am replacing a failed compressor with a like new compressor can I use the electrical components from the old compressor on the new compressor
• You should use only new electrical components (e.g. relay, start capacitor, run capacitor) designed for use with the new compressor. Is it safe to use leak detection dyes in air conditioning and refrigeration systems
• Tecumseh Products Company does not endorse the use of any substance in the system except the oil and refrigerant designed for use in the specific compressor. Do your capacitors contain PCB oil
• Since January 1979, capacitors provided by Tecumseh have contained non-PCB oils. Do your compressors contain PCB's
• No. Do you have a mathematical equation and coefficients for your compressors' performance data
• Yes. We publish compressor performance information to our OEM's in the ARI Standard 540 format. In air conditioning applications, how does horsepower compare to Bth/hr.
• At air conditioning rating conditions one horsepower equals 12,000 Btu/hr. Can I use my own grommets on your compressors
• Yes, if they pass your system shipping/transportation and sound/vibration tests. What is "D21"
• Discharge temperature measured with an insulated T/C two inches from the compressor tube to line joint. Why can't I move the electrical warning label or bar code labels
• Readers or scanners in production are fixed and changing would have to be agreed upon by all customers. Safety reasons govern changing electrical label