Tecumseh Air Conditioning Compressor:
Refrigerant: R-22
Frequency: 60
Volts: 200/230
Phase: 3
BOM No:
Application: AC/HP
RLA: 15.7
LRA: 100
Suction Tube ID: 7/8"
Discharge Tube ID: 1/2"
Shell HT: 13.9
Crankcase Htr:
Oil Recharge:Yes
BTUHs: 57,000
Replaces Compressor Part Numbers:
55-21365-12
55-20892-74
8000-501
55-20881-07
55-22972-26
55-22972-46
55-21471-14
55-20892-27
55-20738-06
8000-556
55-20484-02
55-22972-46P
55-20892-07
GB30KU001
552136512
552089274
8000-501
552088107
552297226
552297246
552147114
552089227
552073806
8000-556
552048402
552297246P
552089207
GB30KU002
WH5800AA
WY5860AA
P031-5451
AS-03586-01
CRT5-0450-TF5
CRT5-0450-TF5-770
P021-5551
912968
55-22319-27S
55-22319-27
P031-5451
AV555E
GB30KV001
GB30KV002
1053109
1053479
1054686
1147122
COM04530
COM4530
1056382
1057168
1147114
AV1900RT-045-B-4C
P031-5751
AV190RT-045-A4Y
AVB5558EXT
CARB92748
CRT50450TF5
GB40LV001
GB40LV011
AVB5558EXT
AV5558E
AV191RT-055-J7
P031-5751
CARAVB5558EXT
CARP0315751.
COMPRESSOR TECHNICAL:
Carrier Compressor Is Used In Air Conditioning Models:
558DPX120000AB
0038
48TJE012510
0038
PY1RPA120180ABWA
0038
PY1RPA120180ABWB
0038
PA1RPA120000ABWA
0038
48TJF006500
0037
PY1RPA120224ABWA
0038
PA1RPA120000ABWB
0038
564APX060000AAAG
0015
PY1RPA120224ABWB
0038
48TJF012510
0038
764APX060000AAAG
0015
PA1ZPA060000AAAA
0015
50ZP060500
0015
580DPV120180AA
0038
580DPV120220AA
0038
580DPV120250AA
0038
558DPX060000AA
0037
580DPV120180AB
0038
580DPV120220AB
0038
580DPV120224AB
0038
580DPV120250AB
0038
50TJ012500
0038
50TJ012800
0038
50TJ012510
0038
50TJ012810
0038
580DPV060074AA
0037
580DPV060115AA
0037
580DPV060150AA
0037
48TJD012500
0038
48TJD006500
0037
48TJE012500
0038
50TJ006500
0037
558DPX120000AA
0038
48TJF012500
0038
PY1RPA060074AAWA
0037
558DQX120000JA
0038
PY1RPA060074AAWB
0037
48TJE006500
0037
PY1RPA060115AAWA
0037
48TJD012510
0038
38YG048500
0015
38YG048510
0015
38TG040810
0014
38TG048500
0014
38YG040810
0015
38YG040820
0015
690APX048000ABAA
0015
690APX048000AAAA
0015
590AQX040000JAAA
0012
590AQX040000JBAA
48TJE012-501GA
48TJE012501GA
590AQX040000AAAA
0012
590APX048000ABAA
580DPV120180ABAA
590APX048000AAAA
0012
690AQX040000JCAA
0015
690AQX040000JBAA
0015
690AQX040000JAAA
0015
690AQX040000AAAA
0015
PY1RPA060115AAWB
48TJE006-501GA
Used in Rheem Ruud Air Conditioning Models:
UAHE-060CAS
RAHE-060CAS
UAHE060CAS
RAHE060CAS
Below are some common questions about our compressors. If you have a question that is not addressed below, please send us an e-mail attention *parts departmaent*. What oil is used in an R-12 compressor manufactured today
• Synthetic alkylate. What is synthetic alkylate oil
• Synthetic alkylate is another name for alkylbenzene, which is used in many of our hermetic compressors. Is 3GS mineral oil compatible with "white oil" and alkylbenzene oil
• Yes. They have different properties, but are chemically compatible. How long may I leave a compressor charged with POE oil open to the atmosphere
• No more than 15 minutes maximum. Can blends be charged as vapor
• No. Blends must be charged in liquid phase. Can R-410A be used in a compressor designed for R-22
• No. Tecumseh is currently developing a line of R-410A compressors. What is the highest acceptable motor winding temperature for your hermetic motors
• 265 degrees Fahrenheit, measured by the resistance method, is the highest acceptable temperature for our hermetic motors. At what speed do your hermetic compressors run
• Our 60 Hz. compressors run at a nominal 3450 rpms at rated voltage, and our 50 Hz. compressors run at 2,875 rpms. Can I use a "one size fits all" type of start relay on all of your hermetic air conditioning compressors
• No. Tecumseh Engineering department has selected specific relays for each compressor to meet there starting specifications. I don't have the correct voltage rating on a run capacitor, as specified in your literature; can I use a different voltage rating
• Yes. The voltage rating of all capacitors must be the same as, or greater than, the specified voltage. If I am replacing a failed compressor with a like new compressor can I use the electrical components from the old compressor on the new compressor
• You should use only new electrical components (e.g. relay, start capacitor, run capacitor) designed for use with the new compressor. Is it safe to use leak detection dyes in air conditioning and refrigeration systems
• Tecumseh Products Company does not endorse the use of any substance in the system except the oil and refrigerant designed for use in the specific compressor. Do your capacitors contain PCB oil
• Since January 1979, capacitors provided by Tecumseh have contained non-PCB oils. Do your compressors contain PCB's
• No. Do you have a mathematical equation and coefficients for your compressors' performance data
• Yes. We publish compressor performance information to our OEM's in the ARI Standard 540 format. In air conditioning applications, how does horsepower compare to Bth/hr.
• At air conditioning rating conditions one horsepower equals 12,000 Btu/hr. Can I use my own grommets on your compressors
• Yes, if they pass your system shipping/transportation and sound/vibration tests. What is "D21"
• Discharge temperature measured with an insulated T/C two inches from the compressor tube to line joint. Why can't I move the electrical warning label or bar code labels
• Readers or scanners in production are fixed and changing would have to be agreed upon by all customers. Safety reasons govern changing electrical label