Accredited Business Go Daddy Authorize.net
Click Here to Learn More
(866) 432-8551 Toll Free
Mon to Fri 10am to 6:30pm EST
Confused? Get help finding the right part
  • Home
  • JOHNSON CONTROLS
  • 20"/100#, M-BLK, OPEN-LO, Outdoor, P70 Series MICRO-SETTM Pressure Control, 4-Wire, 2-Circuit Contac

Rollover image above to zoom

20"/100#, M-BLK, OPEN-LO, Outdoor, P70 Series MICRO-SETTM Pressure Control, 4-Wire, 2-Circuit Contac

Price: $257.17 
Excl. Shipping
In-Stock
SKU: PRS70GE4
(See Product Details Below for Manufacturers Part Numbers)
Quantity:
Discount Shipping

Our volume UPS discounts are passed-on directly to you for the lowest possible shipping rates.













Manufacturer: Johnson Controls

Description: 20"/100#,M-BLK,OPEN-LO,OUTDOOR


Category: Electrical Controls


Sub Category: Pressure Controls


P70 Series MICRO-SETTM Pressure Controls

for Refrigeration and Air Conditioning,

4-Wire, 2-Circuit Contact Block


Application

P70 single and dual function
pressure controls are used in
commercial air conditioning and
refrigeration applications. The
load-carrying contacts provide
direct control of A.C. motors
within the control’s rating. (See
cover label for the electrical
rating.)
The controls can be used with R-
12, R-22, R-500, or R-502
refrigerants. Specific models for
ammonia applications are also
available. The MICRO-SET
construction of low pressure
controls and low side of dual
models permits differentials to a
minimum of 5 psi (34 kPa).




! WARNING: On ammonia
applications, the ammonia
P70 pressure control must

be mounted separately from
the electrical cabinet.



All Series P70 controls are
designed for use only as
operating controls. Where an
operating control failure would
result in personal injury and/or
loss of property, it is the

responsibility of the installer to
add devices (safety, limit
controls) that protect against, or
systems (alarm, supervisory
systems) that warn of control
failure.
Certain models of the Series P70
controls are supplied as
pressure limiting devices for
refrigeration or conditioning
equipment.



Operation

These controls are available with
either main contacts (LINE-M2)
CLOSE high - OPEN low, or
main contacts (LINE-M2) OPEN
high - CLOSE low contact action.
The controls have a four-wire,
two-circuit contact block that
operates from a pressure
actuated bellows.
The controls have a single “sight-set” calibrated scale which
shows cutout setting and the
differential. Adjustments can be
made readily without removing
the control cover.




Installation

Mounting

Mount the control on a flat
surface or panel board by two
screws or bolts through the holes
in the back of the case. The
control should be mounted
above the element connections
to provide drainage from the
sensing elements. The pressure
connection on the bellows should
be above the liquid level of the
equipment on which the control
is used. This reduces possible
accumulation of foreign matter
inside the bellows.



! CAUTION: Do not mount
the control in a position
where dirt, sediment, or oil

will affect the operation of
the control.



Universal mounting bracket
No. 271-51 is available, if
required
.

(Note: When using
any bracket, use only mounting
screws supplied with the control
to prevent damage to internal
components.)



General Instructions

1. Avoid sharp bends or kinks
in the capillary tubing.

2. Be sure pressure controls
installed on ammonia
systems are built for
ammonia service.

3. Purge all tubing and lines
before connecting pressure
controls.

4. Make sure the control is not
installed on equipment to
handle a load in excess of
the switch’s electrical rating.

5. Coil and secure excess
capillary length to avoid
vibration but allow some
slack in the capillary to
avoid “violin string” vibration
which can cause tubing to
break. Do not allow tubing
to rub against metal



Replaces Part Numbers: P70GE-4, CARP70GE-4





I called trying to find out what happened to the rest of my order and was surprised to hear a warm and kind voice willing to do whatever it takes to find answers and follow through with her promise. Amanda is an asset worth holding on to and a credit to your company. She was very professional, helpful and courteous while assisting me with my order. I would most definitely assign her an A+ in customer service."
Donald "Brad" Thomas

I would like to thank you for your hard work in getting us our part in a timely fashion. You were very helpful and you understood the severity of the situation and did a wonderful job in getting the part to us. Thanks again and please share this with your boss! You were outstanding!"
Todd Mills

Share This:
Quantity:
In-Stock
Have Questions? Prefer to order by phone?
Our parts Experts are happy to help!

Call Monday to Friday 10am - 6:30pm EST
1-866-432-8551 or Email our Parts Experts
Accredited BusinessGo DaddyAuthorize.net
Amanda I want to thank you, the blower fan work perfectly. Thank you so very much."
Bill K Roberts
Amanda, Thank you very much again, I have been looking for this part for about two weeks and getting very frustrated in the process of the search, you were very helpful!!"
Ken Holm
Why Buy From Us?
110% Lowest Price Guarantee
Over 500,000 Parts in Stock
Same Day Shipping on Orders Received Before 3pm EST (Mon-Fri)
Nationwide Distribution Centers for Fast Delivery
Choose from UPS Next-Day, 2-Day, 3-Day and Ground Service
We Supply Retail and Wholesale
Order from us.
Risk Free, with
Our Triple Guarantee
Guarantee 1
No hassle, 30-day returns policy
Guarantee 2
110% Lowest price guarantee
Guarantee 3
90-day warranty
Sign up for Special Offers Directly from AmericanHVACParts.com
AmericanHVACParts.com | 548 N. 13th Ave., Suite 302 | Upland, CA 91786
© 2005-2014 AmericanHVACParts.com. All Rights Reserved.