2 Stage Gas Valve, 24 Volt Coil, 1/2" inlet 1/2" outlet. (Carrier) *UPGRADED MODEL

Price: $288.76 
Excl. Shipping
In-Stock
SKU: GSV36E54AC
(See Product Details Below for Manufacturers Part Numbers)
Quantity:
Discount Shipping

Our volume UPS discounts are passed-on directly to you for the lowest possible shipping rates.

NEW UPGRADED GAS VALVE REPLACES OBSOLETE TRANE VALVES



New Upgraded Gas Valve Some Furnace Brands may have wire Harness will need to cut off and put push on clips on the wires

REGULATOR VENT CONNECTION

This valve is shipped with a dust cap installed in the regulator vent connection.

TO INSTALL FITTING:

1. Remove dust cap.
2. Install fitting and turn clockwise until finger tight.
3. Use a wrench to tighten an additional 1⁄4 turn.

SYSTEM WIRING

Refer to and follow the appliance manufacturer's wiring diagram. Refer to fig. 4 for terminal identification.
All wiring should be installed in accordance with local and national electrical codes and ordinances.
Always check that the electrical power supply used agrees with the voltage and frequency shown on the gas control.

CONVERSION FOR L.P. USE

This gas valve incorporates a pressure regulator capable of adjustment for both natural gas and propane gas.
When converting, it is necessary to approximate the low and high fire outlet pressure settings for the new gas prior to reestablishing the gas supply and electrical power to the appliance.
1. Turn off all electrical power to the system at main fuse or circuit breaker.
2. Locate and remove the slotted head high fire cover screw on the side of the gas valve. The location is marked “HI” .
3. Turn the 3⁄32” socket set screw located behind the high fire cover screw clockwise two (2) full turns to approximate the high fire outlet pressure setting.
4. Locate and remove the slotted head low fire cover screw on the top of the gas valve. The location is marked “LO” .
5. Turn the 3⁄32” socket set screw located behind the low fire cover screw clockwise one (1) full turn to approximate the low fire outlet pressure setting.
6. Apply L.P. conversion labels (92-0979 kit, enclosed) to gas valve. Place the “L.P.” dot label on top of the valve, in place of the “NAT. GAS” label. Place the warning label on the exposed side of the gas valve.
7. Turn on the gas supply to the appliance.
This completes conversion of the gas valve for use with L.P. gas.
Return to “Pressure Regulator Adjustment” section and perform final regulator adjustment before placing unit into service.


TECHNICAL SPECIFICATIONS:

Amps:0.54.
Amps High:0.4.
Amps Low:0.3.
BtuH Capacity:210,000.
Coil Volts:24V.
60 Hz.
Gas Type:Natural Gas.
Inlet/Outlet (Inches):1/2" x 1/2".
Capacity AGA Standard Gas:140,000.
Inlet Pressure Tap:Yes.
Opening:1.6" W.C.
Side Taps:No .
Two Stage Snap Open:Yes
Pilot fitting 1/8" NPT Threaded Vent
LP Conversion Kit. H S I/DSI.
System Usage:HSI, or DSI.

Replaces Carrier Gas Valve Part Numbers:

36H64-463 CAR36H64-463 VAL06376 VAL6376 36E54201 36E96-22 VAL03625 VAL3625 36E96-221 CAR36E96221 36F52-204 36E55-203 36E54-214 36E52-209 36E54-200 36E54-203 EF33CW195 EF33CW196 EF33CW198 025-35316-000 C340772P01 EF33CW196A 36E54-201 36E54-208

I called trying to find out what happened to the rest of my order and was surprised to hear a warm and kind voice willing to do whatever it takes to find answers and follow through with her promise. Amanda is an asset worth holding on to and a credit to your company. She was very professional, helpful and courteous while assisting me with my order. I would most definitely assign her an A+ in customer service."
Donald "Brad" Thomas

I would like to thank you for your hard work in getting us our part in a timely fashion. You were very helpful and you understood the severity of the situation and did a wonderful job in getting the part to us. Thanks again and please share this with your boss! You were outstanding!"
Todd Mills

Share This:
Quantity:
In-Stock
Have Questions? Prefer to order by phone?
Our parts Experts are happy to help!

Call Monday to Friday 10am - 6:30pm EST
1-866-432-8551 or Email our Parts Experts
Accredited BusinessGo DaddyAuthorize.net
Amanda I want to thank you, the blower fan work perfectly. Thank you so very much."
Bill K Roberts
Amanda, Thank you very much again, I have been looking for this part for about two weeks and getting very frustrated in the process of the search, you were very helpful!!"
Ken Holm
Why Buy From Us?
110% Lowest Price Guarantee
Over 500,000 Parts in Stock
Same Day Shipping on Orders Received Before 3pm EST (Mon-Fri)
Nationwide Distribution Centers for Fast Delivery
Choose from UPS Next-Day, 2-Day, 3-Day and Ground Service
We Supply Retail and Wholesale
Order from us.
Risk Free, with
Our Triple Guarantee
Guarantee 1
No hassle, 30-day returns policy
Guarantee 2
110% Lowest price guarantee
Guarantee 3
90-day warranty
Sign up for Special Offers Directly from AmericanHVACParts.com
AmericanHVACParts.com | 548 N. 13th Ave., Suite 302 | Upland, CA 91786
© 2005-2014 AmericanHVACParts.com. All Rights Reserved.