Honeywell 24 Volt Dual Direct Spark Ignition or Hot Surface Gas Valve with 1/2 in. x 1/2 in. inlet/outlet, standard opening and 3.5 in. wc pressure regulator setting.
•236B8E
•>
WHEN 0PLACING YOUR PARTS ORDER, YOU CAN ORDER ONLINE 24 HOURS A DAY OR BY CALLING OUR SALES CENTER MONDAY THROUGH FRIDAY 7AM TO 5PM PACIFIC TIME. WE WILL SHIP YOUR PART FROM THE CLOSEST WAREHOUSE PER YOUR ZIP CODE. WE CAN SHIP YOUR PARTS TO YOU NEXT DAY AIR, SECOND DAY AIR OR 3 DAY SELECT OR U.S. POST OFFICE, AND WHEN PLACING YOUR ORDER ONLINE SHIPPING ESTIMATES WILL BE PROVIDED TO YOU FOR EACH SHIPPING CLASS.
Overview
Combination gas controls for use with hot surface/direct spark systems in 24 Vac, gas-fired appliances with capacities from 20 to 200 cfh.
Features
Controls include manual valve, two automatic operators and servo pressure regulator.
Compact size.
Use with S87C,D and S89E,F Control Modules.
Provide two automatic valves.
Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
Diaphragm operated second automatic valve opens under control of the regulator; closes if gas or power supply is interrupted.
Meet codes requiring dual safety shutoff.
Standard and slow opening natural gas models include natural to LP gas conversion kit; LP to natural gas conversion kit also available.
Adjustments and wiring connections are accessible from top of the control.
ON-OFF lighting sequence.
Product Specifications
Type Single Stage
Ignition Type Direct Ignition
Type of Gas Natural
Inlet/Outlet Size (in.) 1/2 in. x 1/2 in.
Body Pattern Straight-through
Opening Characteristics (standard, step) Standard
Capacity @ 1 in. p.d. 150,000 BTU/hr; 20,000 BTU/hr minimum
Pressure Ratings (psi) 1/2 psi
Pressure Ratings (kPa) 3.5 kPa
Pressure Regulator Setting (psi) 3.5 in. wc
Pressure Regulator Setting (kPa) 0.87 kPa
Pressure Tapping 1/8 in. NPT with plug
Electrical Connections 1/4 in. male quick-connects
Electrical Ratings 24 Vac
Frequency 60 Hz
Anticipator Setting 0.5 A
Temperature Range (F) 0 F to 175 F
Temperature Range (C) -18 C to +79 C
Mounting 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Dimensions (in.) 4 15/16 in. high x 4 1/8 in. wide x 2 11/16 in. deep
Dimensions (mm) 125 mm high x 104 mm wide x 69 mm deep
Includes 1/2 in. x 3/8 in. reducer bushing; 39369014 bag assembly-3/4 in. straight flange with O ring, screws and wrench; and 393691 Natural to LP gas conversion kit.
Approvals, American Gas Association IAS AGA Design Certified: File No. L2025006.
Approvals, Canadian Gas Association CGA Design Certified: File No. L2025006.
Approvals, Underwriters Laboratories Inc UL Component Recognized.
Used in Lennox Furnace Models:GS1104E-100-5N-T.
Replaces Gas Valve Part Numbers:
VR8205A2008
624610
025-30251-000
VR8844M1014
VR884M1014
VR8205C1123
VR8205A2156
CARVR8205A2024.
Used in Coleman York Miller Nordyne Furnace Models:
P2MPD20N08001F
P2MPD12N06401A
P2MPD12N06401B
P2MPD12N06401C
PBKM-LD12N060E
PBKMLD12N060E
PBKM-LD12NO60E
M2RC080A16BN
M2RC-080A-BN
PBKM-LD12N080E
PBKMLD12N080E
PBKM-LD12N080
PBKMLD12N080
BDKM-LD08N060F
P1CDD10N05701A
P2MPD20N09601A
P2MPD20NO9601A
.