3-1/2 Ton to 4 Ton Air Conditioning Compressor R-22 208/230 Volts 1-Phase.(Universal Replacement Com

Price: $678.00 
Excl. Shipping
In-Stock
SKU: COMP42K6PFV
(See Product Details Below for Manufacturers Part Numbers)
Quantity:
Discount Shipping

Our volume UPS discounts are passed-on directly to you for the lowest possible shipping rates.

* Copland Replacement Compressor Replaces Obsolete Bristol Models

•236B8E
•>



Compressor Specification:

Evaporator (F) Cond (F):45/130
RG (F) Liq (F): 65/115
Capacity BtuH:41900 to 54700
Power Watts:3860
Current Amps:17.9
EER BtuH/Wh:10.9
Mass Flow Lbs/Hr:615
Number of Cylinders:2
Bore Size (in):1.96
Stroke (in):0.729
Overall Length:10.281"
Overall Width: 9.09
Overall Height: 14.56
Suction Size:3/4"
Discharge Size:1/2"
Initial Oil Charge (oz):45
Oil Recharge (oz):43
RLA: 20.4
LRA Amps:102.0
MCC Amps:28.5
Max Operating Current:
UL File No:SA-2337
CSA File No:LR3104C

Replaces Obsolete Compressor Part Numbers:

H25A4600BCA H25A46QCBCA BM706392 1450-4059A 14504059A 10679708 AVD5542EXN CR42K6-PFV-260 CR42K6PFV920 CR42K6-PFV-920 CR42K6-PFV-877 P021-4229P GB10WF002 GB10WF003 B9266-201 B9266201 CR42K6-PFV-130 CR42K6-PFV-177 H23A423ABCA 703056-06-0705 912959 10481821 10481801 38866C1 38866C4 621328 78H18 78H1801 102064 015-02784-004 01502784004 H21A413ABCA 64C6201 96A477BHAH 307030-352 50SR661330 P031-4221 CR41KQ-PFV980WB CR41KQ-PFV-980WB CR41KQPFV-980WB CR42K6-PFV-960 CR42K6PFV220 CR42K6-PFV-220 H23A423ABCA CR42K6-PFV-270 703202 1090504 AV146ET-005-S7Y AVC5542EXN CR42K6-PFV CR42K6-PFV-230 CR42K6-PFV-270 CR42K6-PFV-26 CARB92738 CARCR41KQPFV980WB CARCR42K6PFV CARCR41KQPFV980WB.

Used in Amana Goodman Air Conditioning Models:

RCC48A2D P1218526C CE48-1FB CE481FB CK48-1C CK481C CPE48-1FB CPE481FB

Used in Air Conditioning and Heating Brands: Airquest, Arcoair, Clare, Comfortmaker, Heil, Kenmore, Tempstar, Snyder General, Intercity Products, Whirlpool and many other brands.

AC10B48 CA4042VKB1

Used in Air Conditioning Models:

BRCQ0481BD BRHS048B R4GA-048K096C R4GA048K096C HS16-4610-4P HS1646104P S3BA-048K S3P9602 S3RA-048K S3RA048K S3QA-048K S3QA048K 50HS-042-311.

Used in Carrier BDP Equipment Models:

38CK042310 38QN042310 38QN042310SM 692ANX042000ABAA 38HPC042300 542GNX042000AEAF 565AJX042000AAAA 565BJX042000AAAA 565BJX042000ABAA 596ANX048000AAAA 38EH042300 38EH042300CD 38EH042300DL 38EH042300SM 38EH042310DL 38EH042320 38EH042320DL 38YH042310 38YH042310DL 77CB042300 77CD042300 544AJX042000AGAA 77CD042310 544BJX042000AAAA 50YQ142300 545BJX042000AGAA 545CJX042000AGAA 38CLC042300 38GP042310 38ER042300 50QQ042380 38TM048300 38TM048300DL 38QH042300 38QH042300BA 38QH042300CD 38QH042300DL 38EHO42320 38QH042300SM 561WJX042000ACAA 561SJX042000ABAA 38CKG042350 561GJX042000AFAA PA10JA04200GADAA PA10JA04200MADAA 38CKS042310 PA10JA042000ADAA 38CKW042340 38YKC042330 561CJX042000AFAA 561CJX04200MAFAA 38CKC042350 38CKC042M350 693DNX042000AEAA 38EB042360 38EC042310 38EC042313 38EC042510 38EC042513 38CKC042350 691ANX042000ABAA 38QH0423003SM

* IMPORTANT!!! - PLEASE NOTE: IDENTIFYING COMPRESSOR FAILURES

Most compressors fail due to system malfunctions, which must be corrected to prevent repeat failures. After a compressor fails, field examination of the failed compressor often will reveal symptoms of system problems. Proper corrections will help eliminate future failures.

* SINGLE PHASE BURN

Two phases of a three-phase motor overheated or burned as a result of the contactor opening only one of its contacts.

Correction:

(1) Replace contactors with properly sized contactors.
(2) Check for proper motor protection.

* HALF WINDING SINGLE PHASE BURN

In a two contactor application, two phases of one half of a three phase motor overheated or burned as a result of one contactor opening only one contact.

Correction:

(1) Replace contactors with properly sized contactors.

* HALF WINDING BURN

Half of all phases on a two contactor three phase motor are overheated or burned due to only one contactor opening.

Correction:

(1) Replace contactors with properly sized contactors.
(2) Check for feed back circuit holding one contactor closed.

* PRIMARY SINGLE PHASE BURN

Only one phase of a three phase motor is overheated or burned as the result of opening one phase on the primary side a delta to wye transformer.

Correction:

(1) Check primary side of a delta to wye main power transformer.

* START WINDING BURN

The start winding only of a single-phase motor is uniformly overheated or burned.

Correction:

(1) Check for proper wiring of compressor.
(2) Check starting capacitor and/or starting relay.
(3) Correct compressor overloading.

* SPOT BURN

A localized burn within a winding, between windings, or from windings to ground. If not the result of mechanical problems, check for spikes or surges of high current flow.

* SHORTED TERMINALS

A break down of the insulation between terminals and compressor body generally the result of over torquing terminals.

I called trying to find out what happened to the rest of my order and was surprised to hear a warm and kind voice willing to do whatever it takes to find answers and follow through with her promise. Amanda is an asset worth holding on to and a credit to your company. She was very professional, helpful and courteous while assisting me with my order. I would most definitely assign her an A+ in customer service."
Donald "Brad" Thomas

I would like to thank you for your hard work in getting us our part in a timely fashion. You were very helpful and you understood the severity of the situation and did a wonderful job in getting the part to us. Thanks again and please share this with your boss! You were outstanding!"
Todd Mills

Share This:
Quantity:
In-Stock
Have Questions? Prefer to order by phone?
Our parts Experts are happy to help!

Call Monday to Friday 10am - 6:30pm EST
1-866-432-8551 or Email our Parts Experts
Accredited BusinessGo DaddyAuthorize.net
Amanda I want to thank you, the blower fan work perfectly. Thank you so very much."
Bill K Roberts
Amanda, Thank you very much again, I have been looking for this part for about two weeks and getting very frustrated in the process of the search, you were very helpful!!"
Ken Holm
Why Buy From Us?
110% Lowest Price Guarantee
Over 500,000 Parts in Stock
Same Day Shipping on Orders Received Before 3pm EST (Mon-Fri)
Nationwide Distribution Centers for Fast Delivery
Choose from UPS Next-Day, 2-Day, 3-Day and Ground Service
We Supply Retail and Wholesale
Order from us.
Risk Free, with
Our Triple Guarantee
Guarantee 1
No hassle, 30-day returns policy
Guarantee 2
110% Lowest price guarantee
Guarantee 3
90-day warranty
Sign up for Special Offers Directly from AmericanHVACParts.com
AmericanHVACParts.com | 548 N. 13th Ave., Suite 302 | Upland, CA 91786
© 2005-2014 AmericanHVACParts.com. All Rights Reserved.