CARRIER, BRYANT, DAY & NIGHT, PAYNE, TRANE UPGRADED DEFROST CIRCUIT BOARD.
Replaces Heat Pump Circuit Board Part Numbers:
HK25SZ359
HK25SZ359A
CEAS410195-01
CEPL110104-02
CEAS410104-01
CEAS410104
CEAS4101-04
HK32FA006
HK32FA003
HK25SZ359
HK25SZ359A
CESO110021-00
P771-1027
HK255Z359
HK25SZ359A
24-ICM320
DFOR-AB1016
DF0R-AB1016
1160719
ICM320
CNT02898
CNT2898
92N83
HK32FA003
HK32FA006
CESO110021-00
P771-1027
CARB13020
HK25SZ359
HK32FA006A
HK32FA006
CARB12480
CARICM320.
It is Highly Recommended when replaceing this Defrost Circuit Board that the Thermostat Sensor Be Replaced at the same time Part Number: HH18HA280A.
Input Control Voltage: 18-30 VAC.
Frequency: 50/60 Hz.
Power Consumption: 1 watt maximum.
Output Type: Maximum Relay.
Form: SPST, normally open.
Rating: 2 amps.
Time Delay Defrost Time: 10 minute fixed +/- 5%.
Interval Time: pin selectable 30/60/90 minute.
Power On Reset Time: 500 milliseconds.
Test Time: Short Across Test Terminals-reduced test time 256x Installation & Diagrams.
1.Disconnect Power.
2.Connect terminals in series with the device.
3.Reapply power and check operation.
Provides a selectable time interval between defrost cycles.
It will allow heat for the selected 30/60/90 minute period and provide a 10 minute defrost.
A hold input permits the timer to accumulate time only while the compressor is running.
Additionally, a warm coil causes the disc sensor to open which will prevent time accumulation or end in an in-progress defrost period.
When the defrost period ends either by opening the DFT or after the 10 minute defrost period has elapsed, the timer is reset.
SEQUENCE OF OPERATION:
•During Heating the
•Y
• terminal is energized, & the time logic is energized.
•Timer tracks compressor run time to the interval selected. 30/50/90.
•When timer sequence is reached, logic checks the status of the defrost thermostat. If the DFT is open, unit does not need defrosting and the timer is reset.
•
•IF DFT is closed, reversing valve is energized, the outdoor fan is turned off, and the strip heat is turned on.(W2).
•
•Maximum of 10 minutes or until the DFT opens.
•
•Defrost sequence configured in the field for 30, 50, and 90 minutes (factory/default set 90 min.)
FORCED DEFROST:
•Jumper the R to DFT terminal on the board
•
•Short the speed up terminal together until the units goes into defrost
•
•As soon as defrost is started remove your jumper from the speed up terminals or the 10 minute defrost will be shorted to 10 seconds
•
•Defrost will stop when 10 minutes has past or as soon as the DFT jumper is removed.
50HX-036 38YG014300 208/230-1-60 38YG018300 208/230-1-60 38YG018310 208/230-1-60 38YG024300 208/230-1-60 38YG030300 208/230-1-60 38YG030310 208/230-1-60 38YG030500 208/230-3-60 38YG030510 208/230-3-60 38YG030703 220/240-1-50 38YG030800 220-3-50 38YG030810 38YGO36300
541DJ018
541DJO24
38YG030900
38YG030910
38QS042300
38QN0243105M
38YCO36310
38YG030920
38YG031300
38YG035800
38YG035810
38YG035900
38YG035910
38YG036300
38YG036310
38YG036500
38YG036510
38YG036600
38YG036610
38YG040810
38YG040820
38YG040910
38YG040920
38YG042300
38YG042310
38YG042500
38YG042510
38YG042600
38YG042610
38YG048300
38YG048310
38YG048330
38YG048500
38YG048510
38YG048530
38YG048600
38YG048610
38YG048630
38YG050800
38YG050810
38YG050900
38YG050910
38YG060300
38YG060500
38YG060600
38YG060810
38YG060820
38YG060900
38YG060910
538BPX060000BAAA
0024
538BPX060000AAAA
0024
538BPX048000BAAA
0024
538BPX048000AAAA
0024
538BPX036000ACAA
0024
538BPX036000BAAA
0024
538BPX036000AAAA
0024
538BEX060000BAAA
0024
538BEX060000AAAA
0024
538BEX060000ABAA
38QN048300SM
38QN048300
538BEX048000BAAA
0024
538BEX048000AAAA
0024
538BEX036000BAAA
0024
538DNX024000AAAA
0034
538DNX018000ACAA
0034
538DNX018000AAAA
0034
538BPX048000ABAA
0024
538BPX048000ACAA
0024
538BNX060000AAAA
0024
538BNX060000BAAA
0024
538BNX048000BAAA
0024
538BNX048000ABAA
0024
538BNX048000ACAA
0024
538BNX048000AAAA
0024
538BNX036000AAAA
0024
538BNX024000BAAA
0024
538BNX030000AAAA
0024
691ANX036000AAAA
538BNX024000AAAA
0024
538BNX024000ACAA
0024
538BNX018000BAAA
0024
538BNX018000AAAA
0024
538BNX018000ACAA
0024
538BEX048000ABAA
0024
538BEX048000ACAA
0024
538BEX036000AAAA
538BEX036000ACAA
0024